Identity and sourcing requirements.
Key technical specifications
Ordering-code highlights reviewed against official manufacturer documentation.
- Function
- Vertical-Hall digital angle sensor · ABZ + PWM pre-configured variant with 14-bit resolution
- Supply voltage
- Functional operating range 3.0 V to 5.5 V
- Supply current
- Functional-range limit (Table 3): 15 mA maximum, applying across the full operating temperature range and the 3.0 V to 5.5 V supply
- Start-up time
- First measurement sample on the interface after 1.5 ms typical / 1.7 ms maximum
- Magnetic induction range
- Operating window 30 mT to 120 mT · the extended 20 mT to 30 mT band carries additional angle error
- Angle error (INL)
- With SysCal enabled, 0.3° maximum (−40°C to +125°C, including lifetime drift); 0.6° maximum over −40°C to +150°C; with SysCal disabled, 0.7° maximum up to +125°C (1.3° maximum to +150°C)
- Angle noise
- RMS noise (an,slow) 0.02° maximum · at TA = 25°C, BXY = 70 mT, filter gains k1 = 2, k2 = 9; over TA = −40°C to +150°C the maximum RMS figure is 0.05° (datasheet Table 7)
- Operating temperature
- AEC-Q100 Grade 0, ISO 26262 ASIL B · operating temperature −40°C to +150°C
- Absolute maximum ratings
- Table 2 absolute-maximum figures — VDD −0.3 V to 7.0 V, TJ = 170°C (time-limited over lifetime) — are not operating values
- Order code
- Infineon OPN TLE49012S0002XTMA1 (SP005858928) · package marking E12S2
- Order-code package
- PG-VSON-8-2, 3 mm × 3 mm · all TLx49012 variants share this package; the marking distinguishes them
- Manufacturer packing
- Tape and reel, 5,000 per the Infineon product page · packing quantity, not stock or MOQ