100+ staff · 1,500+ m² in Shenzhen and Hong Kong · Since 2002
ProductsAnalog ICsMAX6675ISA+T
PACKAGE REFERENCESOIC-8Confirm case, pinout and ordering suffix before purchase.
MANUFACTURER PART RECORD

MAX6675ISA+T

Analog Devices

MAX6675ISA+T is an Analog Devices (Maxim) cold-junction-compensated K-thermocouple-to-digital converter — 12-bit resolution, 0.25 °C per LSB, measuring 0 to +1024 °C, SPI-compatible read-only interface, in SOIC-8, 3 to 5.5 V supply, operating -20 to +85 °C. One chip replacing the thermocouple amplifier, ADC, cold-junction sensor and linearization table is the selection point: a direct digital temperature reading from a type-K probe with open-thermocouple detection, for industrial ovens, appliances and HVAC. Selection advice: this is type-K only and reads 0 °C to +1024 °C — it cannot measure below 0 °C or other thermocouple types, so for sub-zero or multi-type designs look at the MAX31855 family instead. The -20 to +85 °C figure is the chip ambient range, not the measurement range — the thermocouple itself goes to 1024 °C while the chip must stay within its own limits, a distinction that matters in hot enclosures. Choose MAX6675 for simple high-temperature thermocouple jobs and MAX31865 for precision RTD jobs; the two solve different sensor problems and do not substitute. The ISA code is SOIC-8, T denotes tape and reel. Evidence: ADI/Maxim datasheet and distributor listings confirm K-type, 12-bit, 0.25 °C resolution, 0-1024 °C range and SOIC-8.

Analog ICsThermocouple converterSOIC-8
MPN
MAX6675ISA+T
Manufacturer
Analog Devices
Family
Thermocouple converter
Package
SOIC-8
Manufacturer channel coverage
Checked by RFQ
Data last checked
Commercial check required
Required order checks
Suffix, package, date code, lot, source and traceability
PROCUREMENT DATA

Identity and sourcing requirements.

MANUFACTURER DATA REVIEW

Key technical specifications

Ordering-code highlights reviewed against official manufacturer documentation.

Function
Cold-junction-compensated K-type thermocouple-to-digital converter with built-in 12-bit ADC
Resolution / range
12-bit, 0.25°C resolution; reads thermocouple hot junction from 0°C to +1023.75°C; thermocouple accuracy 8 LSBs for 0°C to +700°C
Interface
Simple SPI-compatible read-only serial interface; serial clock up to 4.3 MHz
Diagnostics
Open thermocouple detection
Package / ordering code
8-pin SO (narrow SOIC-8); "ISA" = -20°C to +85°C temp grade; "+" = lead(Pb)-free/RoHS-compliant; trailing "T" = tape and reel
Operating (cold-junction) temperature
-20°C to +85°C — the IC/board cold-junction range, distinct from the +1024°C thermocouple range
Source: Analog Devices/Maxim MAX6675 Cold-Junction-Compensated K-Thermocouple-to-Digital Converter datasheet Rev 3 (19-2235, 6/21) · ordering information · Reviewed 2026-09-28
QUOTE WORKFLOW

Four checks before a commercial offer.

01

Identity

Exact MPN, manufacturer and suffix

02

Supply

Supplier type, quantity and freshness

03

Evidence

Lot, labels, photos and documents

04

Terms

Price, lead time, payment and shipping

RELATED REFERENCES

Explore more Analog ICs records

Browse existing catalog records — same series first, then the same category and manufacturer. These are not confirmed replacements; compatibility requires engineering review.

COMMON QUESTIONS

MAX6675ISA+T FAQ

What are the key specifications of MAX6675ISA+T?

From the verified technical profile: Function: Cold-junction-compensated K-type thermocouple-to-digital converter with built-in 12-bit ADC; Resolution / range: 12-bit, 0.25°C resolution; reads thermocouple hot junction from 0°C to +1023.75°C; thermocouple accuracy 8 LSBs for 0°C to +700°C; Interface: Simple SPI-compatible read-only serial interface; serial clock up to 4.3 MHz. These are the catalog-recorded values for MAX6675ISA+T — always re-check them against the manufacturer datasheet revision quoted on your BOM before finalizing the design.